Fluorescent Emergency Backup Ballast 700


[03-FEB700]
 $57.97  $46.23 

Emergency Ballast

Ensure you have the necessary emergency ballasts for your fluorescent light fixtures to provide secure, safe lighted egress and pathways during interrupted power periods.

Fluorescent Emergency Ballast 700

The FEB7 00 fluorescent emergency ballast works in conjunction with the AC ballast to convert new or existing fluorescent fixtures into emergency lighting. The emergency ballast consists of a high-temperature nickel cadmium battery, charger and electronic circuitry in one compact red case. This ballast can be used with most 17 W through 110 W (2' -8') T8, T10, or T12 fluorescent lamps without integral starters, including U-shaped, HO, VHO, circline, energy saving, and (4-pin) long compacts. It is also compatible with most 1, 2, 3, and 4-lamp electronic, standard, energy saving, and dimming AC ballasts. If used in an emergency-only fixture, no AC ballast is necessary. The FEB700 is not suitable for use in air handling heated air outlet fixtures, and wet or hazardous location fixtures.

Emergency Ballasts Operation

  • When AC power fails, the FEB700 immediately switches to the emergency mode, keeping one lamp illuminated at a reduced lumen output for a minimum of 90 minutes. When AC power is restored, the ballast automatically returns to the charging mode.

Emergency Ballast Installation

  • The FEB700 does not affect normal fixture operation and may be used with either a switched or unswitched fixture. If a switched fixture is used, an unswitched hot lead must be connected to the emergency ballast. The emergency ballast must be fed from the same branch circuit as the AC ballast. The FEB700 may be installed inside, on top of, or remote from the fixture. The emergency ballast may be remote-installed up to half the distance the AC ballast manufacturer recommends remoting the AC ballast from the lamp, or up to 50 feet, whichever is less. Installation is not recommended with fixtures where the ambient temperature may fall below 0°C for extended periods.

UL AND CODE COMPLIANCE

  • The Ballast have been tested by Underwriters Laboratories in accordance with the standards set forth in UL 924, “Emergency Lighting and Power Equipment,” and is UL Listed for factory or field installation. Emergency illumination time exceeds the National Electrical Code (NEC), Life Safety Code (NFPA—LSC) and UL 90-minute requirements.

APPLICATION FEB700

Fluorescent Emergency Backup Ballast 700 Spec Sheet: VIEW
Reviews
Printable Page
Quantity:
 
Reviews
Customers who bought this product also purchased
Compact Fluorescent Flood Light Dual 32wt
Compact Fluorescent Flood Light Dual 32wt
T5 High Bay Fluorescent 4 lamp 54 watt T5HO 120/277
T5 High Bay Fluorescent 4 lamp 54 watt T5HO 120/277
NYC Approved LED Combo Exit Sign, Battery Backup
NYC Approved LED Combo Exit Sign, Battery Backup
Photo Cell 277volt Button
Photo Cell 277volt Button
Low Profile Emergency light, White Battery Backup
Low Profile Emergency light, White Battery Backup
Exit Sign LED Aluminum, Battery Backup, Green/Silver, Single Face
Exit Sign LED Aluminum, Battery Backup, Green/Silver, Single Face
 
 
lighting products